IEC 61936-1 Ed. 2.0 b:2010 - Power installations exceeding 1 kV a.c. (2024)

Historical

Power installations exceeding 1 kV a.c. - Part 1: Common rules

"IEC 61936-1:2010 provides common rules for the design and the erection of electrical power installations in systems with nominal voltages above 1 kV a.c. and nominal frequency up to and including 60 Hz, so as to provide safety and proper functioning for the use intended. For the purpose of interpreting this standard, an electrical power installation is considered to be one of the following:
a) Substation, including substation for railway power supply;
b) Electrical installations on mast, pole and tower; Switchgear and/or transformers located outside a closed electrical operating area;
c) One (or more) power station(s) located on a single site. The installation includes generators and transformers with all associated switchgear and all electrical auxiliary systems. Connections between generating stations located on different sites are excluded;
d) The electrical system of a factory, industrial plant or other industrial, agricultural, commercial or public premises. The electrical power installation includes, among others, the following equipment: rotating electrical machines; switchgear; transformers and reactors; converters; cables; wiring systems; batteries; capacitors; earthing systems; buildings and fences which are part of a closed electrical operating area; associated protection, control and auxiliary systems; large air core reactor. NOTE: In general, a standard for an item of equipment takes precedence over this standard. This standard does not apply to the design and erection of any of the following:
- overhead and underground lines between separate installations;
- electric railways;
- mining equipment and installations;
- fluorescent lamp installations;
- installations on ships and off-shore installations;
- electrostatic equipment (e.g. electrostatic precipitators, spray-painting units);
- test sites;
- medical equipment, e.g. medical X-ray equipment.
This standard does not apply to the design of factory-built, type-tested switchgear for which separate IEC standards exist. This standard does not apply to the requirements for carrying out live working on electrical installations. This second edition cancels and replaces the first edition, published in 2002. It constitutes a technical revision. The main changes with respect to the previous edition are listed below:
- new table of references for additional agreements between manufacturer/contractor/planer and user/orderer/owner (4.1.2);
- addition of minimum clearances in air not standardized by IEC but based on current practice in some countries (Annex A);
- deletion of nominal voltages (Table 1, Table 2, Clause 5);
- addition of regulations for fuses (6.2.15);
- simplification of regulations for escape routes (7.5.4);
- deletion of special regulations for operating aisles (7.5.4);
- modification of clearances for fire protection (Table 3);
- modification of safety criteria for earthing systems (10.2.1);
- modified curves of permissibly touch voltages (Figure 12, Annex B);
- deletion of numbering of subclauses without headlines;
- change of ""should"" to ""shall"" in many cases or change of subclauses with ""should"" to a note."

AVAILABLE FOR SUBSCRIPTIONS

  • ADD TO ALERT
  • PDF

Please first log in with a verified email before subscribing to alerts.

Your Alert Profile lists the documents that will be monitored. If the document is revised or amended, you will be notified by email. You may delete a document from your Alert Profile at any time. To add a document to your Profile Alert, search for the document and click “alert me”.

ADD TO ALERT

Please first verify your email before subscribing to alerts.

Your Alert Profile lists the documents that will be monitored. If the document is revised or amended, you will be notified by email. You may delete a document from your Alert Profile at any time. To add a document to your Profile Alert, search for the document and click “alert me”.

ADD ALERT

Already Subscribed to this document.

Your Alert Profile lists the documents that will be monitored. If the document is revised or amended, you will be notified by email. You may delete a document from your Alert Profile at any time. To add a document to your Profile Alert, search for the document and click “alert me”.

PDF DOCUMENT FORMAT

Documents sold on the ANSI Webstore are in electronic Adobe Acrobat PDF format , however some ISO and IEC standards are available from Amazon in hard copy format.

DRM PROTECTED DOCUMENTS

Some PDF files are protected by Digital Rights Management (DRM) at the request of the copyright holder. You can download and open this file to your own computer but DRM prevents opening this file on another computer, including a networked server. Some copyright holders may impose other restrictions that limit document printing and copy/paste of documents.

NON PRINTABLE DOCUMENTS

Those documents cannot be printed at the request of the copyright holder.

CONTENT PROVIDER
International Electrotechnical Commission [iec]

IEC 61936-1 Ed. 2.0 b:2010 - Power installations exceeding 1 kV a.c. (2024)
Top Articles
Latest Posts
Article information

Author: Otha Schamberger

Last Updated:

Views: 6197

Rating: 4.4 / 5 (75 voted)

Reviews: 82% of readers found this page helpful

Author information

Name: Otha Schamberger

Birthday: 1999-08-15

Address: Suite 490 606 Hammes Ferry, Carterhaven, IL 62290

Phone: +8557035444877

Job: Forward IT Agent

Hobby: Fishing, Flying, Jewelry making, Digital arts, Sand art, Parkour, tabletop games

Introduction: My name is Otha Schamberger, I am a vast, good, healthy, cheerful, energetic, gorgeous, magnificent person who loves writing and wants to share my knowledge and understanding with you.